종목토론카테고리
게시판버튼
게시글 제목
서울아산병원 마취통증의학과 발표 내용게시글 내용
21KF-040 |
Pain research (animal study, neuroscience, big data study, epidemiological study, etc)
|
Kyunghan Jang |
Seon-Soo Choi
|
Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
|
채택 |
21KF-040 |
Analgesic effect of Panaphix in nociceptive pain models of Rats
1Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea<o:p></o:p>
Background
Panaphix (PAX-1, sodium meta-arsenite or NaAsO2) is developed as a therapy for the treatment of various cancer and is known to have analgesic effects. The present study was aimed to investigate the analgesic effects of PAX-1 on nociception in rats.
Methods
The analgesic effect of PAX-1 on nociception was measured using the hot (52.5°C) and cold (2°C) plate test, and surgical incision. Six rats were divided into five groups, respectively; vehicle, 0.1, 1.0, and 10.0 mg/kg of PAX-1, and sham. PAX-1 was orally administered for a week before the hot and cold plate test, and a week after surgery for the treatment of surgical incisional nociception. The analgesic effect was evaluated by measuring the withdrawal threshold to a Von Frey filament in surgical incision group.
Results
Latency of the hot (vehicle vs. 0.1, 1.0, and 10 mg/kg of PAX-1; P=0.008, P=0.006, and P<0.001) and cold plate (vehicle vs. 1.0 and 10 mg/kg of PAX-1; P<0.001, and P<0.001) was significantly prolonged in PAX-1 groups than in vehicle. Compared to vehicle, the Von Frey values were significantly increased in PAX-1 groups when surgical incision test (postoperative day (POD) 1: vehicle vs. 10mg/kg of PAX-1, P=0.002; POD3: vehicle vs. 1.0 and 10 mg/kg of PAX-1, P<0.001 and P=0.008; POD7: vehicle vs. 0.1, 1.0 and 10 mg/kg of PAX-1, P<0.001 in all).
Conclusion
PAX-1 showed preventive and therapeutic effects for incision-evoked mechanical nociception and reduced heat and cold nociception in a rat model, suggesting PAX-1 may have analgesic effects for nociceptive pain.
Panaphix (PAX-1, sodium meta-arsenite or NaAsO2) is developed as a therapy for the treatment of various cancer and is known to have analgesic effects. The present study was aimed to investigate the analgesic effects of PAX-1 on nociception in rats.
Methods
The analgesic effect of PAX-1 on nociception was measured using the hot (52.5°C) and cold (2°C) plate test, and surgical incision. Six rats were divided into five groups, respectively; vehicle, 0.1, 1.0, and 10.0 mg/kg of PAX-1, and sham. PAX-1 was orally administered for a week before the hot and cold plate test, and a week after surgery for the treatment of surgical incisional nociception. The analgesic effect was evaluated by measuring the withdrawal threshold to a Von Frey filament in surgical incision group.
Results
Latency of the hot (vehicle vs. 0.1, 1.0, and 10 mg/kg of PAX-1; P=0.008, P=0.006, and P<0.001) and cold plate (vehicle vs. 1.0 and 10 mg/kg of PAX-1; P<0.001, and P<0.001) was significantly prolonged in PAX-1 groups than in vehicle. Compared to vehicle, the Von Frey values were significantly increased in PAX-1 groups when surgical incision test (postoperative day (POD) 1: vehicle vs. 10mg/kg of PAX-1, P=0.002; POD3: vehicle vs. 1.0 and 10 mg/kg of PAX-1, P<0.001 and P=0.008; POD7: vehicle vs. 0.1, 1.0 and 10 mg/kg of PAX-1, P<0.001 in all).
Conclusion
PAX-1 showed preventive and therapeutic effects for incision-evoked mechanical nociception and reduced heat and cold nociception in a rat model, suggesting PAX-1 may have analgesic effects for nociceptive pain.
랫드의 뇌성 통증 모델에서 파나픽스의 진통 효과
장경환, 김두환, 신진우, 최성수1
1대한민국 울산의과대학교 서울아산병원 마취통증의학과
배경
파나픽스(PAX-1, 메타아르세나이트 나트륨 또는 NaAsO2)는 각종 암 치료를 위한 치료제로 개발돼 진통 효과가 있는 것으로 알려져 있다. 본 연구는 쥐의 신경쇠약에 대한 PAX-1의 진통 효과를 조사하기 위한 것이었다.
방법들
PAX-1이 결찰에 미치는 진통 효과는 고온(52.5℃) 및 저온(2℃) 플레이트 테스트와 수술 절개를 통해 측정했다. 랫드 6마리를 각각 PAX-1 0.1, 1.0, 10.0mg/kg, 가짜 등 5개 그룹으로 분류했다. PAX-1은 온·냉판 검사 전 1주일, 수술 후 1주일 동안 절개 결찰 치료를 위해 경구 투여됐다. 진통 효과는 수술 절개 그룹에서 Von Frey 필라멘트에 대한 금단 임계값을 측정하여 평가되었습니다.
결과.
고온(PAX-1의 차량 대 0.1, 1.0, 10mg/kg; P=0.008, P=0.006, P<0.001) 및 저온판(PAX-1의 차량 대 1.0, 10mg/kg; P<0.001, P<0.001)의 대기시간이 상당히 길어졌다. 수술절개시험(POD) 1 : PAX-1의 차량 대 10mg/kg, POD3 : PAX-1의 차량 대 1.0, P<0.001 및 P.0000의 10mg/kg, POD3 : PAX-1의 차량 대 10mg/kg의 PAX-1, P<0.001 및 P.00;P00)에서 Von Fray 값이 유의미하게 증가하였다.
결론
PAX-1은 랫드 모델에서 절개 유발 기계적 결찰에 예방 및 치료 효과를 보였으며, 이는 PAX-1이 결찰성 통증에 대한 진통 효과가 있을 수 있음을 시사한다.
장경환, 김두환, 신진우, 최성수1
1대한민국 울산의과대학교 서울아산병원 마취통증의학과
배경
파나픽스(PAX-1, 메타아르세나이트 나트륨 또는 NaAsO2)는 각종 암 치료를 위한 치료제로 개발돼 진통 효과가 있는 것으로 알려져 있다. 본 연구는 쥐의 신경쇠약에 대한 PAX-1의 진통 효과를 조사하기 위한 것이었다.
방법들
PAX-1이 결찰에 미치는 진통 효과는 고온(52.5℃) 및 저온(2℃) 플레이트 테스트와 수술 절개를 통해 측정했다. 랫드 6마리를 각각 PAX-1 0.1, 1.0, 10.0mg/kg, 가짜 등 5개 그룹으로 분류했다. PAX-1은 온·냉판 검사 전 1주일, 수술 후 1주일 동안 절개 결찰 치료를 위해 경구 투여됐다. 진통 효과는 수술 절개 그룹에서 Von Frey 필라멘트에 대한 금단 임계값을 측정하여 평가되었습니다.
결과.
고온(PAX-1의 차량 대 0.1, 1.0, 10mg/kg; P=0.008, P=0.006, P<0.001) 및 저온판(PAX-1의 차량 대 1.0, 10mg/kg; P<0.001, P<0.001)의 대기시간이 상당히 길어졌다. 수술절개시험(POD) 1 : PAX-1의 차량 대 10mg/kg, POD3 : PAX-1의 차량 대 1.0, P<0.001 및 P.0000의 10mg/kg, POD3 : PAX-1의 차량 대 10mg/kg의 PAX-1, P<0.001 및 P.00;P00)에서 Von Fray 값이 유의미하게 증가하였다.
결론
PAX-1은 랫드 모델에서 절개 유발 기계적 결찰에 예방 및 치료 효과를 보였으며, 이는 PAX-1이 결찰성 통증에 대한 진통 효과가 있을 수 있음을 시사한다.
게시글 찬성/반대
- 5추천
- 0반대
내 아이디와 비밀번호가 유출되었다? 자세히보기 →
운영배심원의견
운영배심원의견이란
운영배심원 의견이란?
게시판 활동 내용에 따라 매월 새롭게 선정되는
운영배심원(10인 이하)이 의견을 행사할 수 있습니다.
운영배심원 4인이 글 내리기에 의견을 행사하게 되면
해당 글의 추천수와 반대수를 비교하여 반대수가
추천수를 넘어서는 경우에는 해당 글이 블라인드 처리
됩니다.
운영배심원(10인 이하)이 의견을 행사할 수 있습니다.
운영배심원 4인이 글 내리기에 의견을 행사하게 되면
해당 글의 추천수와 반대수를 비교하여 반대수가
추천수를 넘어서는 경우에는 해당 글이 블라인드 처리
됩니다.
댓글목록